AI confirms tracheal tube position on chest radiography

Health News
Tags :
Health News
Share This :


AI confirms tracheal tube position on chest radiography
Left: Chest radiograph from 80-year-old patient in sample A. AI identified endotracheal tube (ETT) with probability score of 0.98, and properly localized tip of ETT (solid arrow). AI also identified tracheal carina with probability score of 0.99 and properly localized carina (open arrow). Based on pixel spacing information in DICOM data header, AI automatically measured absolute distance between ETT tip and tracheal carina (tip-to-carina distance, TCD) as 4.3 cm. AI also measured distance between ETT tip and carina along radiograph’s vertical axis of (y-axis tip-to-carina difference, TCDy) as 4.0 cm, indicating that ETT tip is located 4.0 cm above carina. ETT is in proper position based on TCD. Right: Chest radiograph from 77-year-old patient in sample A. ETT is in critical position, with tip located below tracheal carina. AI-derived TCD was 2.5 cm. AI-derived TCDy was -1.4 cm, indicating that ETT tip is located 1.4 cm below carina. Credit: American Journal of Roentgenology (2023). DOI: 10.2214/AJR.23.29769

According to an accepted manuscript published in the American Journal of Roentgenology, an artificial intelligence (AI) system developed by Lunit (Seoul, Korea) identified improperly positioned endotracheal tube (ETTs) on chest radiographs obtained after ETT insertion, as well as on chest radiographs obtained from patients in the ICU at two institutions.

“Automated AI identification of improper ETT position on chest radiograph may allow earlier repositioning and thereby reduce complications,” wrote corresponding author Eui Jin Hwang, MD, Ph.D., from the department of radiology at Korea’s Seoul National University Hospital.

Hwang et al.’s retrospective study included 539 chest radiographs obtained immediately after ETT insertion from January 1, 2020 to March 31, 2020 in 505 patients (293 men, 212 women; mean age, 63 years) from institution A (sample A); 637 chest radiographs obtained from January 1, 2020 to January 3, 2020 in 304 patients (158 men, 147 women; mean age, 63 years) in the ICU (with or without an ETT) from institution A (sample B); and 546 chest radiographs obtained from January 1, 2020 to January 20, 2020 in 83 patients (54 men, 29 women; mean age, 70 years) in the ICU (with or without an ETT) from institution B (sample C).

Lunit’s commercial DL-based AI system was used to identify ETT presence and measure ETT tip-to-carina distance (TCD). Reference standard for proper ETT position was TCD between 3 cm and 7 cm, determined by human readers. Critical ETT position was separately defined as ETT tip below the carina or TCD less than or equal to 1 cm.

Ultimately, in three patient samples from two different institutions, an AI system identified ETT presence with sensitivity of 99.2–100%; and specificity of 94.5–98.7%, improper ETT position with sensitivity of 72.5–83.7% and specificity of 92.0–100%, and critical ETT position with sensitivity of 100% in all samples and specificity of 96.7–100%.

More information:
Ji Yeong An et al, Artificial Intelligence for Assessment of Endotracheal Tube Position on Chest Radiographs: Validation in Patients From Two Institutions, American Journal of Roentgenology (2023). DOI: 10.2214/AJR.23.29769

Citation:
AI confirms tracheal tube position on chest radiography (2023, September 14)
retrieved 14 September 2023
from https://medicalxpress.com/news/2023-09-ai-tracheal-tube-position-chest.html

This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no
part may be reproduced without the written permission. The content is provided for information purposes only.





Source link

Leave a Reply

Your email address will not be published. Required fields are marked *

Popular News Posts

Categories

Our Exclusive Products

Our Store

Our mission is simple, offer quality products that make our customers lives better at a reasonable price, while ensuring a hassle-free shopping experience. This means that before we bring a product to market, we test it to ensure that it meets our high-level quality standards. Our customer service team understand our products and can answer most every product related question quickly and efficiently. We strive everyday to meet and exceed our customers’ expectations of quality and support! Should we ever fail to meet this expectation – contact us and we will make it right!

Our Value: We are proud of our product and accomplishments, but we typically don’t shout it from the rooftop. Instead, we prefer to let our product and customers do the talking. Our core values can be recognized in our product. The qualities we strive for include:

Pragmatism: We design simple, useful solutions for common needs
Quality: From design to final product, we strive for durable solutions that work
Originality: Creativity and innovation are what makes our product unique
Design: Our minimalist and bold design language focuses on functionality and simplicity that is timeless

0 +

Top Rated Products

0 +

Happy Customers